Warrick Series DF Dual Function Conductivity Level Control

Warrick Series DF Dual Function Conductivity Level Control

  • Solid State Reliability

  • Compact Size

  • Spade Terminals for Easy Wiring

  • Manual Reset (optional)

  • Power Outage Feature (optional)

  • U.L. Limit Control

Dual function Series DF models are designed to control two independent level functions: one single-level control operation and one differential-level operation. Optional Power Outage feature resets after nuisance outages. Optional Reset Button is used when the device has been deactivated due to low-water condition. Reset is activated only after water has returned to normal level. This control is ideal in applications on boilers, food service equipment, and chemical delivery systems.

Contact Design

  • 1 Normally Open & 1 Normally Closed (non-powered)

  • Limit Control - 1 SPDT & Level Control - 1 SPDT

Contact Rating

  • 10 Amp Resistive 1/3 horse power

  • 11 Amp Resistive 1/3 horse power

Control Style

  • Single/Differential Level Service & LLCO

  • Open Board

Enclosure

  • None

  • NEMA 1

  • NEMA 4

Model Type

  • Open Board

Mode of Operation

  • Direct, 10K

  • Direct, 26K

  • Inverse, 10K

  • Inverse

  • Direct, 50K

  • Direct, 100K

  • Inverse, 100K

  • Inverse, 4.7K

  • Inverse, 26K

  • Direct, 4.7K

  • Inverse, 50K

Option Package

  • Reset Function

  • Reset Function, Retrofit Plate

  • Reset Function, Normally Closed Pushbutton, Power Outage, Retrofit Plate

  • Reset Function, Normally Closed Pushbutton, Power Outage, Test Feature

  • Reset Function, Test Feature

  • Reset Function, Normally Closed Pushbutton, Test Feature

  • Reset Function, Power Outage, Test Feature

  • Reset Function, Normally Closed Pushbutton, Power Outage

  • Reset Function, Normally Closed Pushbutton

  • Reset Function, Power Outage

Protection

  • Non-Intrinsically Safe

Sensitivity

  • 50 K ohms

  • 26 K ohms

  • 4.7 K ohms

  • 10 K ohms

  • 100 K ohms

Sensor Type

  • Dual Function Controls

Standoff Style

  • Screw Mount

  • Retrofit

  • 1/16" Panel

  • 1/8" Panel

Supply Voltage

  • 24 VAC

  • 240 VAC

  • 208/240 VAC

  • 120 VAC

Terminal Style

  • Spade Connection

Time Delay (decreasing level) H/L function

  • 00

  • 04

  • 10

Time Delay (decreasing level) LLCO function only

  • 06

  • 05

  • 10

Time Delay (increasing level) H/L function

  • 00

  • 04

  • 10

Product Family

  • Dual Function Conductivity Level Control

Maximum Operating Temperature [°F]

  • 150 °F

Minimum Operating Temperature [°F]

  • -40 °F

 

Inquiry Form

Our partners in other countries

Amtest-TM Kft. (HU) - Attila Polgar Amtest PL (PL) - Dariusz Koziello Amtest-TM ELTH srl (RO) - Bogdan Valcea ADELANTEST Ltd (RUS) - Igor Kozlov GIGA Electronic Ltd. - Danail Georgiev OÜ Est-Doma (EST) Promix Ltd. (UA) - Oleksandr Labuzov Vildoma (LT, LV)

We cooperate with partners and resellers in other European countries

View partners